{"id":121,"date":"2011-12-27T17:49:42","date_gmt":"2011-12-27T17:49:42","guid":{"rendered":"http:\/\/www.mayoda.ca\/en\/?page_id=121"},"modified":"2012-05-04T02:03:07","modified_gmt":"2012-05-04T02:03:07","slug":"lesatec","status":"publish","type":"page","link":"https:\/\/www.mayoda.ca\/en\/lesatec\/","title":{"rendered":"Lesatec"},"content":{"rendered":"<p><strong>Lesatec<\/strong> was established in 1996 in order to work in Contamination Control Plants and Equipments sector.<\/p>\n<p><strong>Lesatec<\/strong> provides the following services:<\/p>\n<ul>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/home.htm\" target=\"_blank\"><strong>Clean Rooms<\/strong><\/a> design and construction<\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/home.htm\" target=\"_blank\"><strong>HVAC systems<\/strong><\/a> for Clean Environments design and construction<\/li>\n<li>Devices for Contamination Control design and construction<\/li>\n<li>Isolators design and construction<\/li>\n<li>Clean Environments Validation<\/li>\n<li>Work Direction<\/li>\n<li>Turnkey plants building<\/li>\n<li>Research in fields like particles, air and temperature distribution<\/li>\n<\/ul>\n<p><strong>PRODUCTS<\/strong><br \/>\n<strong>Lesatec<\/strong> developed a large set of products and accessories for\u00c2\u00a0<a href=\"http:\/\/www.lesatec.com\/inglese\/prodotti.htm\" target=\"_blank\"><strong>Clean Rooms<\/strong><\/a> and for systems dedicated to <a href=\"http:\/\/www.lesatec.com\/inglese\/prodotti.htm\" target=\"_blank\"><strong>contamination control<\/strong><\/a>.<\/p>\n<ul>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/unitaventilazioneuni.htm\" target=\"_blank\"><strong>UNIDIRECTIONAL AIR FLOW VENTILATION UNIT<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/mv12.htm\" target=\"_blank\"><strong>MV12\/3<\/strong><\/a> | <a href=\"http:\/\/www.lesatec.com\/inglese\/mv24.htm\" target=\"_blank\"><strong>MV24\/3<\/strong><\/a>| <a href=\"http:\/\/www.lesatec.com\/inglese\/mv36.htm\" target=\"_blank\"><strong>MV36\/3<\/strong><\/a> | <a href=\"http:\/\/www.lesatec.com\/inglese\/mv48.htm\" target=\"_blank\"><strong>MV48\/3<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/refrigeratori.htm\" target=\"_blank\"><strong>REFRIGERATORS FOR GMP CLASSIFIED ENVIRONMENT<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/generetorenebbia.htm\" target=\"_blank\"><strong>FOG GENERATOR<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/isolatore.htm\" target=\"_blank\"><strong>ISOLATOR FOR HANDLING OF API<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/boxdipassaggio.htm\" target=\"_blank\"><strong>PASS BOX WITH U.V. LAMPS<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/distributorearia.htm\" target=\"_blank\"><strong>AIR DISTRIBUTOR FOR SURGERY ROOMS<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/cappadowncross.htm\" target=\"_blank\"><strong>DOWN FLOW BOOTH<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/docciaaria.htm\" target=\"_blank\"><strong>AIR SHOWERS<\/strong><\/a><\/li>\n<li><a href=\"http:\/\/www.lesatec.com\/inglese\/pressurizzatore.htm\" target=\"_blank\"><strong>INSULATION PRESSURIZER<\/strong><\/a><\/li>\n<\/ul>\n<div align=\"left\">\n<table width=\"100%\" border=\"2\" cellspacing=\"0\" cellpadding=\"0\" align=\"left\">\n<tbody>\n<tr>\n<td valign=\"top\">ISOLATOR FOR ACTIVE PHARMACEUTICAL NGREDIENTS (API) HANDLING<\/p>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><img loading=\"lazy\" decoding=\"async\" class=\"alignright  wp-image-915\" title=\"leasatec1\" src=\"http:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec1-290x300.jpg\" alt=\"\" width=\"232\" height=\"240\" srcset=\"https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec1-290x300.jpg 290w, https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec1.jpg 350w\" sizes=\"auto, (max-width: 232px) 100vw, 232px\" \/>Isolator for Active Pharmaceutical ingredients is an equipment dedicated either to the handling of toxic \/ harmful pharmaceutical powders or to the handling of sterile products.<br \/>\nIt is composed of two separated environments, one dedicated to the proper handling, the other to the inlet \/ outlet of products. Each environment is provided with a vertical &#8211; unidirectional <a href=\"http:\/\/www.lesatec.com\/inglese\/isolatore.htm\" target=\"_blank\"><strong>air flow<\/strong><\/a> <a href=\"http:\/\/www.lesatec.com\/inglese\/isolatore.htm\" target=\"_blank\"><strong>ventilation<\/strong><\/a> device ISO 5 class (complying ISO 14644).<br \/>\nThe accurate internal aerodynamics make this device suitable for precision weighing operations, eliminating the problem of air speed influence on pans of precision balance.<br \/>\nWork desks, removable, are made with AISI 304 or AISI 316 pipes in order to make cleaning operations easy and effective.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\" wp-image-916 alignleft\" title=\"leasatec2\" src=\"http:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec2-300x225.jpg\" alt=\"\" width=\"232\" height=\"174\" srcset=\"https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec2-300x225.jpg 300w, https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec2.jpg 350w\" sizes=\"auto, (max-width: 232px) 100vw, 232px\" \/>Under work desks there is a collection tank for powders or for washing \/ sanitizing solutions.<br \/>\nUnit design allows to guarantee a self-safe functioning in both conditions of works (positive &#8211; negative pressures).<br \/>\nMoreover unit external surfaces cleaning characteristics allow its use inside classified environments ISO5 .<\/p>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright  wp-image-917\" title=\"leasatec3\" src=\"http:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec3-241x300.jpg\" alt=\"\" width=\"193\" height=\"240\" srcset=\"https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec3-241x300.jpg 241w, https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/leasatec3.jpg 350w\" sizes=\"auto, (max-width: 193px) 100vw, 193px\" \/>Main characteristics:<\/strong><\/p>\n<ul>\n<li>Negative \/ positive pressure rate settable for each environment<\/li>\n<li>Complete AISI 304 or AISI 316 construction<\/li>\n<li>Primary filtration stage for inlet air : prefilters efficiency G4<\/li>\n<li>Terminal ULPA filtration stage for inlet air : ULPA filters efficiency U15<\/li>\n<li>Primary filtration stage for exhaust air made with HEPA filters (efficiency H13) installed, inside safe change filter housing with bag in \/ bag out system, upstream of exhaust fan<\/li>\n<li>Secondary filtration stage for exhaust air made with HEPA filters (efficiency H12 or H13) installed downstream of exhaust fan<\/li>\n<li>Exhaust fan inside the unit<\/li>\n<li>Automatic pressures and air flows control made with Lesatec dedicated PLC suitable for remote connection with PC<\/li>\n<\/ul>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Accessories:<\/strong><\/p>\n<ul>\n<li>Vacuum cleaning system with connection inside each environment<\/li>\n<li>Chemical inertization system of tanks, walls and work desks inside isolator<\/li>\n<li>Particles continuos monitoring system<\/li>\n<li>Microbiological monitoring system<\/li>\n<li>HPDS Lesatec sterilization system, using dry vapours of H2O2, with continuos control of peroxide concentration<\/li>\n<\/ul>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>MV48\/3 type 5<\/strong><img loading=\"lazy\" decoding=\"async\" class=\"alignright  wp-image-918\" title=\"MV48-3 type 5\" src=\"http:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/MV48-3-type-5-300x216.jpg\" alt=\"\" width=\"240\" height=\"173\" srcset=\"https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/MV48-3-type-5-300x216.jpg 300w, https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/MV48-3-type-5.jpg 350w\" sizes=\"auto, (max-width: 240px) 100vw, 240px\" \/><\/p>\n<ul>\n<li>Dimensions: 1270 x 660 x 590 mm.<\/li>\n<li>Weight: c.a. 100 Kg<\/li>\n<li>Feed: 230v 50-60Hz<\/li>\n<li>Power: 650 W<\/li>\n<li>Maximum absorbed current: 2,84 A<\/li>\n<li>Nominal air flow: 1200 m3\/h<\/li>\n<li>Medium speed unidirectional flow: 0,46 m\/s<\/li>\n<li>Maximum Cleanliness Class: ISO 5 (0,5 um)<\/li>\n<li>Noise level at 1 meter: 61 dB(A)<\/li>\n<\/ul>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Models:<\/strong><\/p>\n<ul>\n<li>LESATEC GN3-2 Type1<\/li>\n<li>LESATEC GN5-2 Type1<\/li>\n<li>LESATEC GN5-2 Type1D<\/li>\n<\/ul>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Technical data:<\/strong><\/p>\n<ul>\n<li>Overall dimensions: 190x360xh350 mm<\/li>\n<li>Tare weight: 12 Kg<\/li>\n<li>Solution tank capacity: 1500 mL<\/li>\n<li>Usable quantity for each load: 1200 mL<\/li>\n<li>Residuo non nebulizzabile per ogni carica: 300 mL<\/li>\n<li>Generate water particles diameter: &gt;20 \u00ce\u00bcm<\/li>\n<li>Electrical feeding: 230V \/ 1F \/ 50Hz<\/li>\n<li>Max air flow rate: 12 m3\/h<\/li>\n<li>Max solution temperature for correct running: 50 \u00c2\u00b0C<\/li>\n<li>Min. solution temperature for correct running: 0 \u00c2\u00b0C<\/li>\n<li>Fog generation capability:<\/li>\n<ul>\n<li>Mod.: GN3-0: 450 mL\/h<\/li>\n<li>Mod.: GN5-0: 850 mL\/h<\/li>\n<\/ul>\n<li>Max power consumption:<\/li>\n<ul>\n<li>Mod: GN3-01: 140 Watt<\/li>\n<li>Mod: GN5-01: 200 Watt<\/li>\n<\/ul>\n<\/ul>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>DOWN FLOW BOOTH<img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-914\" title=\"DOWN FLOW BOOTH2\" src=\"http:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/DOWN-FLOW-BOOTH2-224x300.jpg\" alt=\"\" width=\"224\" height=\"300\" srcset=\"https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/DOWN-FLOW-BOOTH2-224x300.jpg 224w, https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/DOWN-FLOW-BOOTH2.jpg 350w\" sizes=\"auto, (max-width: 224px) 100vw, 224px\" \/><\/strong><\/p>\n<div align=\"center\"><\/div>\n<p>Down Flow Booth is an equipment designed and realized for powders handling, weighing and sampling operations able to:<\/p>\n<ul>\n<li>allow the creating of an unidirectional air flow at class ISO5 (0,5 micron) following ISO14644 classification<\/li>\n<li>protect operators from powders inhalation or contact<\/li>\n<li>protect products from external environment contaminations<\/li>\n<li>protect external environment from powders outflowing.<\/li>\n<\/ul>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<\/td>\n<\/tr>\n<tr>\n<td><strong>Main characteristics:<\/strong><\/p>\n<ul>\n<li>Complete AISI 304 construction<\/li>\n<li>Air filtration in protected area : HEPA H14<\/li>\n<li>Return air primary filtration stage: G4<\/li>\n<li>Return air second stage filtration: F9 or HEPA H13 with safe change housing (Canisters) for API (Active Pharmaceutical Ingredients) handling<\/li>\n<li>Protected area bordered with transparent and flexible curtains or rigid partitions<\/li>\n<li>Exhaust air filtration: HEPA H14<\/li>\n<li>Protected area Contamination Class: ISO 5 (ISO14644-1)<\/li>\n<li>Air flow regulation and control system<\/li>\n<li>Leak Test probes<\/li>\n<li>Lighting system<\/li>\n<li>Air cooling system on request<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p><strong>AIR SHOWER<\/strong><\/p>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-912\" title=\"AIR SHOWER\" src=\"http:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/AIR-SHOWER-175x300.jpg\" alt=\"\" width=\"175\" height=\"300\" srcset=\"https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/AIR-SHOWER-175x300.jpg 175w, https:\/\/www.mayoda.ca\/en\/wp-content\/uploads\/2011\/12\/AIR-SHOWER.jpg 280w\" sizes=\"auto, (max-width: 175px) 100vw, 175px\" \/>Air shower is an equipment suitable to be used inside production environments where it is necessary to lpowders or fibres transport during the passage of operators between adjacent rooms. This scope is achieved by means of the operator &#8220;air washing&#8221;, during the transit inside the air shower, made with high speed shoots of HEPA filtered air.<\/p>\n<p>Working principle is based on high speed air shoots capability to remove particles from clothes surfaces.<\/p>\n<p>HEPA filtration of air before its diffusion inside the Air Shower make it qualified for its use inside Contamination Controlled Environments.<\/p>\n<div align=\"center\">\n<hr align=\"center\" noshade=\"noshade\" size=\"1\" width=\"100%\" \/>\n<\/div>\n<p><strong>Main characteristics:<\/strong><\/p>\n<ul>\n<li>Complete AISI 304 construction<\/li>\n<li>Overall standard dimensions : 1100 x 1200 x h 2750 mm<\/li>\n<li>Useful standard dimensions : 800 x 1100 x h 2100 mm<\/li>\n<li>Feed : 400V \/ 3F \/ 50Hz<\/li>\n<li>Power : 2,5 kW<\/li>\n<li>Contamination Class in \u00e2\u20ac\u0153At Rest\u00e2\u20ac\u009d condition : ISO 5 (ISO14644)<\/li>\n<li>Lighting system<\/li>\n<li>Flow management of staff fulfilled with interlocked doors and traffic lights<\/li>\n<li>Cycles length settable<\/li>\n<li>Emergency unlock pushbutton for doors<\/li>\n<li>DOP Test probes<\/li>\n<li>Different sizes available<\/li>\n<\/ul>\n<p dir=\"rtl\">\n","protected":false},"excerpt":{"rendered":"<p>Lesatec was established in 1996 in order to work in Contamination Control Plants and Equipments sector. Lesatec provides the following services: Clean Rooms design and construction HVAC systems for Clean Environments design and construction Devices for Contamination Control design and construction Isolators design and construction Clean Environments Validation Work Direction Turnkey plants building Research in &hellip; <\/p>\n<p><a class=\"more-link block-button\" href=\"https:\/\/www.mayoda.ca\/en\/lesatec\/\">Continue reading &raquo;<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-twocolumnsleft.php","meta":{"footnotes":""},"class_list":["post-121","page","type-page","status-publish","hentry","nodate"],"_links":{"self":[{"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/pages\/121","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/comments?post=121"}],"version-history":[{"count":33,"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/pages\/121\/revisions"}],"predecessor-version":[{"id":509,"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/pages\/121\/revisions\/509"}],"wp:attachment":[{"href":"https:\/\/www.mayoda.ca\/en\/wp-json\/wp\/v2\/media?parent=121"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}